Series 40CR
[Series 2500CRR]
Home
»
SCR
»
Series 2500CRR
Electrical Characteristics Maximum Ratings
Symbol
Units
RMS Forward Current
IT (RMS)
A
99
Average
Forward Current
IT (AV)
A
63
Peak One-cycle Surge @ 8.3ms.
IT SM
A
1,172
I2t @ 8ms.
I2t
A2/sec
7,049
Maximum Forward Voltage Drop @ 25°C at Noted Amps
VTM
V
A
90
195
Maximum Voltage Ratings
VRRM
VDRM
V
1,400
Maximum Thermal Resistance Junction to Case
°C/W
0.35
Maximum Rate of Rise on State Current (non-rep.)
di/dt
A/µ sec.
400
Minimum Critical Exponential Rate of Rise Off - State Voltage
dv/dt
125°
V/µ sec.
200
Maximum Gate Voltage to Trigger
VGT
V
3.00
Maximum Non Triggering Gate Voltage
VGD
V
0.25
Typical Gate Current to Trigger
IGT
MA
100
Maximum Turn Off Time 200 Volts/µ second reapplied
Tq
µ second
10-25
Mechanical Characteristics
For Tq Add Letter "X" and Turn Off time After Voltage
Mounting Torque
-----
inch Lbs.
30
Thread Size
-----
-----
1/4-28
Mounting Force PSI Gauge
MIN
Lbs.
-----
MAX
Maximum Operating Temperature on All SCRs (TJ)=125°C
SCR NOMENCLATURE
All SCRs are negative base. Flat packs have one polarity, to reverse, point the arrow of the polarity sign to the side you want positive. When the amperage of the device is unknown, check the stud or puck size and select a device of the same size with the highest rating available. When the voltage of the device is unknown, use the transformer secondary voltage or the dc voltage times 2.5 for device voltage.