10 Common Causes of SCR problems / failures
Learn more about our Model M3K SCR and Diode Tester
Learn more about our Model M3K SCR and Diode Tester

Click Here

Series 350CR

Download PDF of this page  Print this page
Home » SCR »
 

Electrical Characteristics Maximum Ratings Symbol Units  
RMS Forward Current IT (RMS) A 550
Average
Forward Current
IT (AV) A 350
Peak One-cycle Surge @ 8.3ms. IT SM A 10,000
I2t @ 8ms. I2t A2/sec 416,000
Maximum Forward Voltage Drop @ 25°C at Noted Amps VTM V


A
1,100
Maximum Voltage Ratings VRRM
VDRM
V 2,000
Maximum Thermal Resistance Junction to Case °C/W 0.09
Maximum Rate of Rise on State Current (non-rep.) di/dt A/µ sec. 800
Minimum Critical Exponential Rate of Rise Off - State Voltage dv/dt
125°
V/µ sec. 300
Maximum Gate Voltage to Trigger VGT V 3.00
Maximum Non Triggering Gate Voltage VGD V 0.15
Typical Gate Current to Trigger IGT MA 150
Maximum Turn Off Time 200 Volts/µ second reapplied Tq µ second  
Mechanical Characteristics       For Tq Add Letter "X" and Turn Off time After Voltage
Mounting Torque ----- inch Lbs. 300
Thread Size ----- ----- 3/4-16
Mounting Force PSI Gauge MIN Lbs. -----
MAX

Maximum Operating Temperature on All SCRs (TJ)=125°C



SCR NOMENCLATURE
All SCRs are negative base. Flat packs have one polarity, to reverse, point the arrow of the polarity sign to the side you want positive. When the amperage of the device is unknown, check the stud or puck size and select a device of the same size with the highest rating available. When the voltage of the device is unknown, use the transformer secondary voltage or the dc voltage times 2.5 for device voltage.

 

 
 