Series 350CR
Home
»
SCR
»
Electrical Characteristics Maximum Ratings
Symbol
Units
RMS Forward Current
IT (RMS)
A
550
Average
Forward Current
IT (AV)
A
350
Peak One-cycle Surge @ 8.3ms.
IT SM
A
10,000
I2t @ 8ms.
I2t
A2/sec
416,000
Maximum Forward Voltage Drop @ 25°C at Noted Amps
VTM
V
A
1,100
Maximum Voltage Ratings
VRRM
VDRM
V
2,000
Maximum Thermal Resistance Junction to Case
°C/W
0.09
Maximum Rate of Rise on State Current (non-rep.)
di/dt
A/µ sec.
800
Minimum Critical Exponential Rate of Rise Off - State Voltage
dv/dt
125°
V/µ sec.
300
Maximum Gate Voltage to Trigger
VGT
V
3.00
Maximum Non Triggering Gate Voltage
VGD
V
0.15
Typical Gate Current to Trigger
IGT
MA
150
Maximum Turn Off Time 200 Volts/µ second reapplied
Tq
µ second
Mechanical Characteristics
For Tq Add Letter "X" and Turn Off time After Voltage
Mounting Torque
-----
inch Lbs.
300
Thread Size
-----
-----
3/4-16
Mounting Force PSI Gauge
MIN
Lbs.
-----
MAX
Maximum Operating Temperature on All SCRs (TJ)=125°C
SCR NOMENCLATURE
All SCRs are negative base. Flat packs have one polarity, to reverse, point the arrow of the polarity sign to the side you want positive. When the amperage of the device is unknown, check the stud or puck size and select a device of the same size with the highest rating available. When the voltage of the device is unknown, use the transformer secondary voltage or the dc voltage times 2.5 for device voltage.
Quantity: