Home
|
About
|
Part Finder
|
Contact Us
My Account
|
View Quote (0)
|
Submit Quote
Search
Parts
Diodes
SCR
SCR/Diode Test Equipment
Part Finder
10 Common Causes of SCR problems / failures
Learn more about our Model M3K SCR and Diode Tester
Click Here
Series 150CR
Home
»
SCR
»
Electrical Characteristics Maximum Ratings
Symbol
Units
RMS Forward Current
IT (RMS)
A
235
Average
Forward Current
IT (AV)
A
150
Peak One-cycle Surge @ 8.3ms.
IT SM
A
4,000
I2t @ 8ms.
I2t
A2/sec
66,000
Maximum Forward Voltage Drop @ 25°C at Noted Amps
VTM
V
A
1,000
Maximum Voltage Ratings
VRRM
VDRM
V
1,600
Maximum Thermal Resistance Junction to Case
°C/W
0.13
Maximum Rate of Rise on State Current (non-rep.)
di/dt
A/µ sec.
800
Minimum Critical Exponential Rate of Rise Off - State Voltage
dv/dt
125°
V/µ sec.
300
Maximum Gate Voltage to Trigger
VGT
V
3.00
Maximum Non Triggering Gate Voltage
VGD
V
0.15
Typical Gate Current to Trigger
IGT
MA
150
Maximum Turn Off Time 200 Volts/µ second reapplied
Tq
µ second
10-25
Mechanical Characteristics
For Tq Add Letter "X" and Turn Off time After Voltage
Mounting Torque
-----
inch Lbs.
300
Thread Size
-----
-----
3/4-16
Mounting Force PSI Gauge
MIN
Lbs.
-----
MAX
Maximum Operating Temperature on All SCRs (TJ)=125°C
SCR NOMENCLATURE
All SCRs are negative base. Flat packs have one polarity, to reverse, point the arrow of the polarity sign to the side you want positive. When the amperage of the device is unknown, check the stud or puck size and select a device of the same size with the highest rating available. When the voltage of the device is unknown, use the transformer secondary voltage or the dc voltage times 2.5 for device voltage.
Quantity: