10 Common Causes of SCR problems / failures
Learn more about our Model M3K SCR and Diode Tester
Learn more about our Model M3K SCR and Diode Tester

Click Here

Series 1250CRH

Download PDF of this page  Print this page
Home » SCR »
 

Electrical Characteristics Maximum Ratings Symbol Units  
RMS Forward Current IT (RMS) A 1,965
Average
Forward Current
IT (AV) A 1,250
Peak One-cycle Surge @ 8.3ms. IT SM A 27,000
I2t @ 8ms. I2t A2/sec 3,040,000
Maximum Forward Voltage Drop @ 25°C at Noted Amps VTM V


A
160
2,500
Maximum Voltage Ratings VRRM
VDRM
V 2,400
Maximum Thermal Resistance Junction to Case °C/W 0.03
Maximum Rate of Rise on State Current (non-rep.) di/dt A/µ sec. 600
Minimum Critical Exponential Rate of Rise Off - State Voltage dv/dt
125°
V/µ sec. 200
Maximum Gate Voltage to Trigger VGT V 3.00
Maximum Non Triggering Gate Voltage VGD V 0.15
Typical Gate Current to Trigger IGT MA 150
Maximum Turn Off Time 200 Volts/µ second reapplied Tq µ second 250
TYP
Mechanical Characteristics       For Tq Add Letter "X" and Turn Off time After Voltage
Mounting Torque ----- inch Lbs. -----
Thread Size ----- ----- -----
Mounting Force PSI Gauge MIN Lbs. 5,000
MAX 6,000

Maximum Operating Temperature on All SCRs (TJ)=125°C



SCR NOMENCLATURE
All SCRs are negative base. Flat packs have one polarity, to reverse, point the arrow of the polarity sign to the side you want positive. When the amperage of the device is unknown, check the stud or puck size and select a device of the same size with the highest rating available. When the voltage of the device is unknown, use the transformer secondary voltage or the dc voltage times 2.5 for device voltage.

 

 
 
  Quantity:
 
   
 